Additional charges may be incurred from Police Services for their response. Notify site; in no response; notify contacts; in no response; advise Emergency Services.
ADT may pass these charges onto the customers. Notify site; in no response; notify contacts; if no response dispatch patrol unless not authorised. Additional charges may be incurred for Patrol response. Note: Customers receiving Supervised Monitoring services, a schedule of hours must be listed. The Interactive Voice Response system provides a telecommunications solution allowing ADT to deliver safe, accurate and speedy alarm notifications directly to our customer.
This platform offers customers the ability to interact with ADT via their telephone keypad. Once an IVR call has been answered, S. I will introduce the importance of the call. It will prompt the customer to press any key to continue. The address and alarm event will be advised followed by key options that the customer can select from depending on their choice of alarm response. For accounts with Supervised Monitoring, S.
I will notify you at the time of your expected business close and offer you the option of extending that time by up to 4 hours in one hour increments. I call has just been missed, customers also have the ability of returning the number that contacted them.
What happens if the contacts listed presses an incorrect key on the phone when responding to this notification? I will allow 3 attempts to enter the correct information via the keypad before ending the call and moving to the next contact, repeating the steps outlined above.
I has the option to transfer the call to our Monitoring Centre so that you can receive additional information from an operator if you require it. There are no additional charges for our customers if you want to be transferred to the operations center. What benefits does my property get from using this system? By using this system ADT will be able to offer you;.
I, but if we do experience any significant downtime, we have duplicated infrastructure in Sydney and Melbourne that will meet our disaster recovery standards. The customer must return the equipment to ADT on termination of the contract. Help reduce your carbon footprint. Switch to e-Invoicing. Alarm FAQs. Frequently Asked Questions How do I determine which device in my system requires a battery replacement? Panel Low Battery Your alarm system battery supplies backup power to operate your alarm system during a power outage.
You can find this out in a number of ways. Did I replace the old battery with the correct battery? Have I correctly connected the wiring to the new battery? Why do I still have a low battery light on my keypad? How do I reset it? Regards, Security Response Centre.
Power Fail A Power Fail signal is received when your security system registers a loss of mains power to the security system. What are some of the other reasons my security system has lost power? The Power Fail signal may be caused by some of the following: Mains supply failure in your area Blown fuse on the premise Power point has failed Cleaner removed the power pack Power pack has come loose in the socket or has accidentally been removed Power pack has failed.
What can I check? If you are experiencing a black out in your area there is nothing you can do until power has been restored. If your power is off for several days, your alarm panel may need minor reprogramming after the power has been restored Check your keypad to see if your power light has restored, if it has then this indicates that the mains power has recovered. Locate your power pack, this looks like an oversized phone charger , and feel it, it should be warm to the touch if working OK.
If the power pack is cold, remove it and plug it back in, then check the keypad power light to confirm if the power has been restored. If nothing has worked, test the power point by plugging in another electrical device. If this device works then try the power pack again, if it has failed use an extension lead to plug the power pack into another power point.
Sensor Trouble This signal is a non-alarm event that indicates that a sensor circuit is not complete. What action I need to take? Your alarm system must have an active standard phone connection to operate properly.
The most common things that can cause this alarm signal to happen could be: Recent power failure that caused the panel to fully shut down. Change of phone provider. Repairs to your phone lines in the house. Local floods Wilful or accidental damage to your phone lines off site. Disconnecting your phone line from the exchange. Having the phone off the hook during the time that the panel is trying to communicate.
Fail to Close A Fail to Close signal is received if the monitoring centre has not received the arming signal from your premises by the time prescribed.
Fail to Open A Fail to Open signal is received if the monitoring centre has not received the disarm signal from your premises by the time prescribed. Loss of RF Supervision The Loss of RF Supervision signal indicates that one of your wireless devices is not correctly communicating to the main alarm panel. Possible causes: As the batteries in a device get weaker, the signals range is reduced to the point where the device is no longer within the range of the main panel.
Some large or dense metal object has been introduced between the device and the main panel. The device has become faulty. Possible solutions: Change the batteries in the device Remove the metal object or have a technician reposition the device. Have a technician replace the faulty device. Protection Loop Short A Protection Loop Short indicates that you might have some faulty wiring for a particular zone or a faulty alarm panel.
Sounder Loop Short A Sounder Loop Short indicates that you might have some faulty wiring from the alarm panel to the external siren or a fault in the alarm panel.
Irregular Open Irregular Open An Open signal is received at the monitoring centre when a correct code is used to turn off disarm the alarm system at your premises. If this signal occurs frequently, please call option 1 to update your opening schedule. Some possible causes of Sensor tampers may be: 1 If an intruder cuts the wire going to device. Bypass A Bypass signal indicates that a zone has either been automatically or manually programmed not to send a signal.
To disarm your system , tap the red icon. Category: home and garden home security. Luckily, minor issues like this do not require that you contact ADT to resolve. Step 1: Locate the reset button on your ADT alarm keypad. How do I troubleshoot my ADT alarm? How do I stop my ADT alarm from beeping?
How do I reset my alarm system? How to Reset a Home Alarm System. Check the manufacturer's website for installer instructions. What is a tamper alarm? How do you reset your house alarm after a power cut? Locate the "System" or "System Status" button on your home alarm keypad. How do I reset my alarm without the code?
How to reset the installer code. Unplug the transformer from the power source. How do I reset the code on my ADT alarm? Press the star key on the keypad in the control console, followed by the number 5. How do I stop my house alarm from beeping with low battery? Most standard systems will allow you to stop the beeping using one of the following methods:. Disarm your system by entering your unique code. How do I turn off my ADT alarm without the code?
Why is my house alarm beeping? What does check long range radio mean on ADT alarm? Can you still use ADT alarm without monitoring? What happens if I unplug my ADT system? Can you use an alarm system without monitoring? Why does my ADT Alarm say trouble? How do I reset my ADT alarm battery? Press the "Status" button on the panel two times.
How do I turn off my ADT alarm system? Receive a call from one of our experienced security consultants at a convenient time for you. Schedule a Call Availability Call Date. Call time All times are in CST. First Name. Last Name. Phone Number.